High-speed 2D Optical Micrometer
TM-3000 series
Specs High-speed 2D Optical Micrometer TM-3000 series
| 
         Model  | 
        
         TM-006  | 
        
         TM-040  | 
        
         TM-065  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Measuring range  | 
        
         ø6 mm  | 
        
         ø40 mm  | 
        
         ø65 mm  | 
    |||
| 
         Minimum detectable object  | 
        
         0.04 mm  | 
        
         0.3 mm  | 
        
         0.5 mm  | 
    |||
| 
         Transmitter/receiver distance  | 
        
         60 mm  | 
        
         180 mm  | 
        
         270 mm  | 
    |||
| 
         Light source  | 
        
         GaN Green LED  | 
        
         InGaN Green LED  | 
    ||||
| 
         Measurement accuracy  | 
        
         ±0.5 µm*1  | 
        
         ±2 µm*5  | 
        
         ±3 µm*7  | 
    |||
| 
         Repeatability  | 
        
         ±0.06 µm*2  | 
        
         ±0.15 µm*6  | 
        
         ±0.2 µm*8  | 
    |||
| 
         Sampling cycle (trigger interval)  | 
        
         5.5ms (33ms at the initial setting)*3  | 
    |||||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP64*4  | 
    ||||
| 
         Ambient temperature  | 
        
         0 to +50 °C  | 
    |||||
| 
         Relative humidity  | 
        
         35 to 85 % RH (No condensation)  | 
    |||||
| 
         Material  | 
        
         Aluminium  | 
    |||||
| 
         Weight  | 
        
         Transmitter  | 
        
         Approx 140 g  | 
        
         Approx 560 g  | 
        
         Approx 1280 g  | 
    ||
| 
         Receiver  | 
        
         Approx 340 g  | 
        
         Approx 720 g  | 
        
         Approx 1460 g  | 
    |||
| 
         Base  | 
        
         Approx 220 g  | 
        
         Approx 630 g  | 
        
         Approx 1500 g  | 
    |||
| 
         *1 In a measurement area of 2 mm x ø4 mm error when measuring width of KEYENCE standard object (glass calibration scale).  | 
    ||||||
| 
         Model  | 
        
         TM-3001  | 
        
         TM-3001P  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
    |||
| 
         Head compatibility  | 
        
         Compatible  | 
    ||||
| 
         Number of connectable sensors  | 
        
         2 units max.*1  | 
    ||||
| 
         Display  | 
        
         Minimum display unit  | 
        
         0.01 µm, 0.001 mm2, 0.01 °  | 
    |||
| 
         Maximum display range  | 
        
         ±9999.99 mm, ±99999.9 mm2, ±99999.9°  | 
    ||||
| 
         Input terminal block  | 
        
         Laser remote interlock input  | 
        
         Non-voltage input*2  | 
    |||
| 
         Trigger input (for Head A)  | 
        
         Non-voltage input*2  | 
        
         Voltage input*2  | 
    |||
| 
         Timing 1 input  | 
    |||||
| 
         Auto-zero 1 input  | 
    |||||
| 
         Reset input  | 
    |||||
| 
         Output terminal block  | 
        
         Analogue voltage output  | 
        
         ±10 V x 2 outputs, out put impedance: 100 Ω*2  | 
    |||
| 
         Total judgment output  | 
        
         NPN open-collector output*2  | 
        
         PNP open-collector output*2  | 
    |||
| 
         Error output  | 
        
         NPN open-collector output (N.C.)*2  | 
        
         PNP open-collector output (N.C.)*2  | 
    |||
| 
         Process output  | 
        
         NPN open-collector output*2  | 
        
         PNP open-collector output*2  | 
    |||
| 
         Trigger input enable output  | 
    |||||
| 
         Adjusted error output  | 
    |||||
| 
         Expansion connector  | 
        
         Trigger input (for Head A)  | 
        
         Non-voltage input*2  | 
        
         Voltage input*2  | 
    ||
| 
         Timing 2 input  | 
    |||||
| 
         Auto-zero 2 input  | 
    |||||
| 
         Programme switching input  | 
        
         Non-voltage input, 4 inputs*2  | 
        
         Voltage input, 4 inputs*2  | 
    |||
| 
         Memory card save input  | 
        
         Non-voltage input*2  | 
        
         Voltage input*2  | 
    |||
| 
         Judgment/Binary output  | 
        
         3-level judgment output: OUT1 to OUT16, total judgment output  | 
        
         3-level judgment output: OUT1 to OUT16, total judgment output  | 
    |||
| 
         Strobe output  | 
        
         NPN open-collector output*2  | 
        
         PNP open-collector output*2  | 
    |||
| 
         Trigger input enable output  | 
    |||||
| 
         Analogue RGB monitor output  | 
        
         SVGA (800 x 600 pixels)  | 
    ||||
| 
         RS-232C interface  | 
        
         Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable)  | 
    ||||
| 
         USB interface  | 
        
         In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible)  | 
    ||||
| 
         Ethernet interface  | 
        
         1000BASE-T/1000 BASE-TX/10 BASE-T  | 
    ||||
| 
         Memory card  | 
        
         SD card CA-SD4G (4GB), CA-SD1G (1GB) support  | 
    ||||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC ±10 %, Ripple (P-P) 10 % or less  | 
    |||
| 
         Current consumption  | 
        
         1 head connected 480mA max./ 2 heads connected 550mA max.  | 
    ||||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +50 °C  | 
    |||
| 
         Relative humidity  | 
        
         35 to 85 % RH (No condensation)  | 
    ||||
| 
         Material  | 
        
         Polycarbonate  | 
    ||||
| 
         Weight  | 
        
         Approx. 1,120 g  | 
    ||||
| 
         *1 1 or 2 units can be connected only with the same head model  | 
    |||||