Communication Unit
N-R2/R4/UB/L20 series
Dedicated Communication Unit, RS-422A/485 Type N-R4
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | N-R4  | |||
Interface  | RS-422A/485  | |||
Code reader power supply  | 5 VDC ±5% (650 mA)  | |||
Terminal block  | Input  | Number of inputs  | 2 inputs (IN1 and IN2)  | |
Input type  | Bidirectional voltage input  | |||
Maximum rating  | 26.4 VDC  | |||
Minimum ON voltage  | 15 VDC  | |||
Maximum OFF current  | 1 mA  | |||
Output  | Number of outputs  | 4 outputs (OUT1 to 4)  | ||
Output type  | Photo MOS relay output  | |||
Rated load  | 30 VDC, 100 mA  | |||
Leakage current when OFF  | 0.1 mA or less  | |||
Residual voltage when ON  | 1 V or less  | |||
Communicationspecifications  | Head port  | Number of inputs  | 1 (12-pin round connector)  | |
Supported communication standards  | RS-232C compliant  | |||
Communication speed  | 4800, 9600, 19200, 31250, 38400, 115200 bit/s  | |||
Data bit length  | 7/8 bits  | |||
Stop bit length  | 1/2 bits  | |||
Parity check  | None/even/odd  | |||
Communication specifications  | Communication standard  | RS-422A/RS-485 (Maximum connectable units: 31) Switchable  | ||
Connector  | 1 (removable 5-pole connector)  | |||
Communicationspecifications  | Output interface  | Total extension length  | 1.2km or less  | |
Rating  | Power voltage  | 24 VDC +10 %, -20 %  | ||
Current consumption  | 380 mA or less  | |||
Environmental resistance  | Ambient temperature  | 0 to +50 °C (No freezing)  | ||
Relative humidity  | 35 to 85 % RH (No condensation)  | |||
Storage temperature  | -20 to +60 °C (No freezing)  | |||
Operating environment  | No dust or corrosive gas present  | |||
Vibration resistance  | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions  | |||
Weight  | Approx. 135 g (excluding connector)  | |||