High-speed Static Elimination Blower
SJ-F020 series
Recommended Replaceable Products: Multi-Sensor Ionizer - SJ-F700 series
Contact Us: 1800-396-5010(Singapore) +65-6392-1011 Enquiry form
Blower Type Main Unit SJ-F020
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | SJ-F020 | |||
Ion generation method | Corona discharge method | |||
Voltage application method/applied voltage | Pulse DC method | |||
Applied voltage | ±8000 V | |||
Ion balance control method | I.C.C. method | |||
Static elimination time (±1000 V to ±100 V) | 1 sec. or less *1*2 | |||
Ion balance | ±10 V or less *1 *2 | |||
Maximum air volume | 3.0m3/min | |||
Maximum wind speed | 2.5 m/s *1 | |||
Control input | From electrostatic sensor only | |||
Controloutput | Type | To an additional static elimination blower | ||
Alarm output | NPN open collector: 100 mA max. (40 V max.) N.C., | |||
Ozone density | 0.005 ppm or less *1 | |||
Major functions | Feedback from static electricity sensor (SK-200), air volume adjustment, alarm output | |||
Rating | Power voltage | 24 VDC ±10 % | ||
Current consumption | 800 mA or less | |||
Environmental resistance | Ambient temperature | 0 to +50 °C | ||
Relative humidity | 35 to 65 % RH (No condensation) | |||
Weight | Static elimination blower: Approx. 1.5 kg | |||
*1 When measured at the centre of the air outlet, 300 mm from the front surface of the blower, at the maximum air velocity. |