Electrostatic SensorSK series

Sensor Head

SK-030

[Discontinued model]

This model has been discontinued.

Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products
To contact us:

SPECIFICATIONS

Select Language

Model

SK-030

Type

Sensor head

Measurement method

V.S.S. method

Measurement mode

High-precision mode,Wide-range mode

Measurement range

High-precision mode

0 to ±5 kV

Wide-range mode

0 to ±30 kV

Measurement accuracy

High-precision mode

±10 V*1*2

Wide-range mode

±3% of F.S.*3*2

Analogue voltage output

Output voltage

High-precision mode

±5 V

Wide-range mode

±3 V

Output impedance

100 Ω

Sampling time

0.1 sec.

Control input

Type

Program (P1, P2, P3), Timing, Hold-reset

Signal

NPN or Non-voltage contact signal

Controloutput

Tolerance judgement

HI/GO/LO,
NPN : 100 mA max. (40 V max.) N.O.

Response time

0.2 sec. (at No. of averaging measurements : 1)

Major functions

Feedback input to the SJ-F020 static eliminator blower type, Measurement
No. of averaging measurements setting, Various hold,
Upper/lower limit setting, Panel-lock, Program selection

Control output

Alarm output

NPN : 100 mA max. (40 V max.) N.C.

Rating

Power voltage

24 VDC ±10 %

Current consumption

600 mA or less

Environmental resistance

Ambient temperature

0 to +50 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Special polycarbonate

Weight

Approx. 330 g (including the 3 m cable)

*1 Obtained with a measurement distance of 8 to 12 mm and an electrostatic charge of ±100 V or less. When the charge is ±100 V to ±5 kV, the measurement accuracy is ±10% of the measured value.
*2 When ambient temperature is fixed at 25°C.
*3 Obtained with a measurement distance of 68 to 72 mm.