The multi-function amplifier with an all-in-one design
Internal calculations are possible for all kinds of
applications.
This device is equipped with an all-in-one add/subtract function
that focuses PLC data and reduces programming hours.
With conventional devices, calibration had to be conducted on every
individual sensor head, however, the IL Series has a
dedicated mode that allows calibration to be completed in 3 simple
steps.
Bring the target close to one sensor head and input the thickness data, then push the set button.
Bring the same target used in Step 1 close to the opposing sensor head and push the set button.
Insert a target thicker than the target used in Step 2. Input the thickness data. Then pushing the set button completes calibration.
When bringing the target closer to the sensor head in Steps 1 and
2, you are compensating for the misalignments that occur during
installation.
To set, you can begin with either one of the sensor heads.
This function identifies step edges automatically and delivers one-shot output for each step. Create settings for count and seam detection applications easily, without the programming hours.