Multi-Purpose CCD Laser Micrometer
IG series
Sensor Head IG-028
 
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
| Model | IG-028 | |||
| Operation principle | CCD method | |||
| Light source | Wavelength | 660 nm (Visible light semiconductor laser) | ||
| FDA | Class 1*1 | |||
| IEC/JIS | Class 1 | |||
| Mounting distance | 0 to 1500 mm | |||
| Measurement range | 28 mm | |||
| Sampling cycle | 980 µs (When the number of times for averaging is set to [hsp]: 490 µs) | |||
| Minimum detectable object | High sensitivity mode | ø0.1 mm (Setting distance: 100 mm)*2 | ||
| Standard mode | ø0.2 mm (Setting distance: 50 mm), | |||
| Repeatability | 5 µm (Setting distance: 100 mm) | |||
| Linearity | ±0.1 % of F.S. (±28 µm)*4 | |||
| Temperature characteristics | ±0.01 % of F.S./°C (±3 µm/°C)*5 | |||
| Operation indicator | Transmitter | Optical axis alignment indicator: Green LED | ||
| Receiver | Optical axis alignment indicator: Green LED | |||
| Environmental resistance | Enclosure rating | IP67 | ||
| Ambient light | Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6 | |||
| Ambient temperature | -10 to +45 °C (No freezing) | |||
| Relative humidity | 35 to 85 % RH (No condensation) | |||
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis | |||
| Material | Case | Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part) | ||
| Lens cover | Glass | |||
| Cable | PVC | |||
| Accessories | Transmitter × 1, Receiver × 1, Sensor head cables (2 m) × 2 | |||
| Weight | Approx. 500 g (including supplied items) | |||
| *1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice. | ||||
 