Panel-mounted PLC with Built-in Display Functions

KV-P series

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Base unit, DC type, 10 Inputs and 6 Relay Outputs KV-P16R

KV-P16R - Base unit, DC type, 10 Inputs and 6 Relay Outputs

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

KV-P16R

General specifications

Environmental resistance

Operating ambient temperature

0 to 50°C (no freezing)*1

Operating ambient humidity

35 to 85%RH (no condensation)

Ambient temperature for storage

-20 to 70°C (no freezing)

Withstand voltage

1,500 VAC for 1 minute (between the power supply terminal and the I/O terminals and between all the external terminals and the case)

Noise immunity

1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator)

Ambient operating atmosphere

Minimal amount of dust and corrosive gas present

Overvoltage category

I

Allowable instantaneous outage time

Less than 2 ms

Structure

Panel-mount type, only the operation part of the front surface has a rating of IP65.

Power voltage

24 VDC ± 10%

Internal current consumption

220mA or less

Environmental resistance

Insulation resistor

50 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and the I/O terminals and between all the external terminals and the case)

Impact resistance

Conforms to JIS B 3502 and IEC 61131-2, 147 m/s2, operating time: 11 ms, 3 times in each of the 3 directions

Pollution degree

2

Vibration resistance

Intermittent vibration

Frequency: 10 to 57 Hz

Amplitude: 0.075 mm*2

Frequency: 57 to 150 Hz

Acceleration: 9.8 m/s2*2

Continuous vibration

Frequency: 10 to 57 Hz

Amplitude: 0.035 mm*2

Frequency: 57 to 150 Hz

Acceleration: 4.9 m/s2*2

Weight

Approx 415g

Function specifications

Data access panel

Display power

LCD display with 3-colour backlight

Character size

Full-width: 7.00 mm × 7.80 mm, half-width: 3.48 mm × 7.80 mm

Data name display

Negative and positive displays, blinking display, scroll display Half-width characters: fixed display: 14 characters, scroll display: 64 characters Full-width characters: fixed display: 7 characters, scroll display: 32 characters

Data display

Sign, up to 10 digits with decimal point

Display device

All devices (registered with the panel editor)

Data change

By way of the front panel switch

Reset function

By way of the RESET switch

Key protection function

By way of the front panel switch

Other

Indirect specification can be used to display messages.

Message panel

Display power

LCD display with 3-colour backlight

Character size

Full-width: 7.00 mm × 7.80 mm, half-width: 3.48 mm × 7.80 mm

Message view

Negative and positive displays, blinking display, scroll display Same size half-width characters: fixed display: 14 characters, scroll display: 64 characters Same size full-width characters: fixed display: 7 characters, scroll display: 32 characters Same size vertical half-width characters: fixed display: 14 characters, scroll display: 64 characters, Same size vertical full-width characters: fixed display: 7 characters, scroll display: 32 characters ×4 half-width characters: fixed display: 7 characters, scroll display: 64 characters ×4 full-width characters: fixed display: 3 characters, scroll display: 32 characters (When same size vertical characters or ×4 characters are displayed, the second line cannot be used to display nameplates.)

Nameplate display

2 full-width characters (4 half-width characters) × 3 nameplates, positive display

Function switch

F1 to F5, 5 total (F2 to F4 have nameplate displays.)

Other

Indirect specification can be used to display data.

Performance specifications

Arithmetic control method

Stored program method

I/O control method

Refresh method

Programming language

Ladder chart method + expansion ladder method

Instruction type

Basic instructions: 28 kinds, application instructions: 22 kinds, calculation instructions: 26 kinds, interrupt instructions: 4 kinds

Minimum scan time

140 µs

Instruction processing speed

Basic instruction

0.7 µs minimum

Application instruction

6.4 µs minimum

Program capacity

4,000 steps

Expansion unit: Maximum number of units that can be attached

8 (excluding the QL-B1)

KL interface

None

Number of inputs/outputs (the KV-P main unit, includes 16 inputs/outputs)

16 to 2,064 (when extended to the maximum number of KL Series units), 16 to 272 (when extended to the maximum number of QL Series units), 16 to 144 (when extended to the maximum number of expansion units)

Internal auxiliary relay

2,560 relays, 1,000 to 1,915 and 3,000 to 17,915 (including the relays for the QL Series)

Special auxiliary relay

160 relays, 2,000 to 2,915

Data memory

2,000 words, DM0000 to DM1999

Temporary data memory

32 words, TM00 to TM31

Timer/counter

0.1 s timer: TMR (0 to 6,553.5 s) 0.01 s timer: TMH (0 to 655.35 s) 0.001 s timer: TMS (0 to 65.535 s) Addition counter C Up/down counter UDC Total: 250

Digital trimmer

2

High-speed counter

30 kHz, 2-phase high-speed counter × 2 (count from 0 to 65,535)*3

High-speed counter comparator

4 (2 equipped for each high-speed counter), direct output possible

Positioning control function

1 independent axis, 50 kHz maximum

Memory switch

16

Power off holding function

Program memory

Flash ROM rewritable 100,000 times or more

Data memory, counter, internal auxiliary relay, contact comment (retention devices are set by MEMSW instructions)

120 days or more (at 25°C) through use of electric double-layer capacitors, flash ROM can be used to back up data

Self-diagnosis function

CPU error, RAM error

Peripheral equipment

Programming console KZ-P3, ladder support software KV BUILDER (version 4 or later)

Number of contact comments

1,000 contact comments maximum can be recorded

*1 These are the values when installed with a vertical orientation. Refer to the instruction manual for details on all other installations.
*2 Conforms to JIS B 3502, IEC61131-2
Number of sweeps: 10 times respectively in the X, Y, and Z directions (80 minutes)
*3 These can be set to 24 bits.

Data Sheet (PDF) Other Models