About software updates
About software updates
MAJOR CHANGES/REVISION HISTORY
CHANGES FROM 3.44 TO 3.45
2. Fixed bugs
- We have corrected the following defect: When Combine multi measurement is started at specific time, measurement results on appropriate dates cannot be extracted from "Statistics/Analysis”. This may happen when Time Zone is set other than to "(UTC+09:00) Osaka, Sapporo, Tokyo"
CHANGES FROM 3.30 TO 3.40
1. Added Functions
- Added selection check box to enable/disable the Inspect Sink Marks and Flash function in the Save Consolidated Measurements Data confirmation dialogue box
2. Fixed bugs
- Fixes made to prevent the selection of a focus indicator when performing a positioning search with the IM-6140
- Fixed bug that causes an error when the size of the dimension line arc in the Angle Measurement Results is very small
- Changed to specifications to allow the Z stage to maintain its focus position when auto-focus is used with Multi Measurement
- Fixed bug that sometimes causes the misalignment of the Image and Edge Point Trail Display when performing Consolidated Measurement
CHANGES FROM 3.04 TO 3.30
1. Added Functions
- Added language switching function (Japanese/English/German/French/Italian/Simplified Chinese/Traditional Chinese/Korean/Thai)
2. Fixed bugs
- Changed calculation method for Length of Internal Processing Time During Measurement when Virtual Line is unlimited
CHANGES FROM 3.03 TO 3.04
2. Fixed bugs
- Changed specifications to automatically return the Z-stage to the point of origin when returning to the menu screen from Measurement Settings or Multi Measurement. Z-stage height is maintained during measurement.
CHANGES FROM 2.95 TO 3.03
1. Added Functions
- Supports IM-6120/6025/6015
- Added Average No. of Measurements Settings function
- Added Pattern Search Active Region settings
- Added function that allows the Z-stage to be manually adjusted for measurement (IM-6120/6140 only)
- Added Manual Measurement function
- Added Automatic Transition Settings function to Combined Settings
- Added Adjust Scan Interval function to Profile Extraction Elements
CHANGES FROM 2.92 TO 2.95
1. Added Functions
- Added Data Output function to IM-H1T IM Data Transfer Software
- Reduced measurement time when a large quantity of measurement objects are measured in succession
CHANGES FROM 2.81 TO 2.92
1. Added Functions
- Added Italian and Thai to the Language Switching function
CHANGES FROM 2.71 TO 2.81
1. Added Functions
- Added French and Traditional Chinese to Language Switching function
CHANGES FROM 2.62 TO 2.71
1. Added Functions
- Added German and Chinese to Language Switching function
CHANGES FROM 2.53 TO 2.62
1. Added Functions
- Added Language Switching function (Japanese/English)
CHANGES FROM 2.33 TO 2.53
1. Added Functions
- Added "Peak Line", "Peak Circle", "Peak Arc", and "Gauge Line" to Element Tools
- Added "Linear Pitch Angle", "Circular Pitch Width", "Area Measurement", and "Thread Measurement" to Application Tools
- Added "Tolerance Judgement" selection function to all pitch measurements
- Added "Inscribed and Circumscribed Circle" to Virtual Line
- Added a function that can specify other measurement results in the radius specification for "Parallel Lines" and "Auxiliary Circle"
- Added "Output Pattern" selection to "Auxiliary Circle"
- Supports Maximum/Minimum Material Tolerance in "Straightness", "Perpendicularity", "Parallelism", "Point Position", and "Concentricity"
- Possible to select a custom folder to save CSV files
- Improved the order of numbering for Batch Measurements
- Added Specify Pattern search direction
- Added Measurement Results Sorting function when performing Batch Measurements
- Improved auto-focus performance for the IM-6140
- Added DXF Export function
- Possible to select up to four decimal places for the angle display digits
- Possible to perform direct input in the entry field for "Manager" from the Multi Measurement screen
- Batch Depth Composition Image Display supported
- Added Clear All Tolerances
- Added "Consolidated Measurement Settings" to Password Protection in the Security Settings. Separated "Measurement Settings" and "Single Measurement"
- Removed the Save Measurement Settings function in "Single Measurement"
- Changed design value for "Profile Line Output" to dashed line
- Increased File History Display in Multi Measurement Mode and Measurement Settings Mode to 50 items
- Set lighting conditions at the end of Multi Measurement to lighting conditions when the Measurement Settings Data has been saved
CHANGES FROM 2.22 TO 2.33
1. Added Functions
- Added French and Traditional Chinese to Language Switching function
CHANGES FROM 2.20 TO 2.22
2. Fixed bugs
- Fixed Profile Line Output Display bug from the Statistics/Analysis screen
CHANGES FROM 2.10 TO 2.20
1. Added Functions
- Added German and Chinese to Language Switching function
- Changed the minimum area size in Pattern Registration
- Added Expand Screen function in the Pattern Registration dialogue
CHANGES FROM 2.08 TO 2.10
1. Added Functions
- Added Language Switching function (Japanese/English)
- Added Time Zone Settings function
CHANGES FROM 2.07 TO 2.08
1. Added Functions
- Added "Speed Priority"/"Accuracy Priority" selection to Pattern Image Registration
CHANGES FROM 1.58 TO 2.07
2. Fixed bugs
- Reduced processing time when Reference Coordinates are being set
CHANGES FROM 1.58 TO 2.06
1. Added Functions
- Supports IM-6140 measurement head
- Added "Point Position" and "Perimeter Length" to Application Tools
- Added Individual Dimension Display to Pitch Measurement
- Supports the creation of elements in Application Tools
- Added "Profile" to GD&T (geometric dimensioning and tolerances)
- Added "Profile Extraction" and "Automatic Generation" to Element Tools
- Changed the layout of the Element Tools Edit Screen
- Added π, ARC functions, and CRD functions to Calculations
- Added Batch Measurement (Pattern Search No. Settings) function
- Added Consolidated Measurement Settings function
- Added Layer Control function
- Added Profile Statistics to Statistics/Analysis
- Added File Search function to Statistics/Analysis
- Added Element Batch Edit/Sort function
- Added Folder Settings function
- Supports network folders
- Network sharing and FTP servers made always accessible
- Added Device Identification Name Settings function
- Added CSV file Auto-creation function
- Added Serial Counter function
- Added Auto-save Image when NG/Fail Occurs function
- Changed Display Digits Settings function
- Added Batch Auto-focus function
- Added Switch Results Display function
- Added Depth Composition function
- Added Copy Reference Point function, Rotate&Copy function, Invert Horizontally& Copy function, and Invert Perpendicularly&Copy function for elements
- Added Expand/Reduce Element function
- Added Overlapping Guide
CHANGES FROM 1.56 TO 1.58
2. Fixed bugs
- Fixed bug that prevented measurement values from being updated directly after switching to the Details Display from the Expanded Display in Multi Measurement
- Fixed bug that sometimes displayed the message, "Perform edge extraction and then save" in error when saving measurement settings
- Fixed bug that sometimes would cause freezing when overwriting the "Measurement/Settings Data Specification Area" display when saving measurement settings
CHANGES FROM 1.52 TO 1.56
2. Fixed bugs
- Fixed bug that caused switching to Expanded Display when performing Multi Measurement
- Fixed bug that did not allow measurement when setting reference coordinates based on an Auxiliary Circle
- Fixed bug related to the transfer of data when overwriting a save with Save As
CHANGES FROM 1.38 TO 1.52
1. Added Functions
- Added Measurement Direction Specification function to "Point-Point", "Circle-Point", and "Circle-Circle" in Basic Measurements
- Added "Point (on an Arc)" and "Maximum/Minimum Point (Circle/Arc) to Element Tools
- Added Edge Extraction Parameters Auto-adjustment function to Element Tools
- Added "White Centre" and "Black Centre" to Edge direction in Element Tools
- Added "Maximum Circle" and "Minimum Circle" output function to Circle in Element Tools
- Supports custom axis for "Line Passing through Point" in Virtual Line
- Supports two-point specification for "Auxiliary Circle" in Virtual Line
- Supports Print All for the Label Printer
- Changed maximum number of setting elements to 650 items
2. Fixed bugs
- Applied .NET Framework, SP2 (Fixed bug that sometimes causes problems in which .NET Framework bugs would cause a forced exit or freezing.)
- Fixed bug that sometimes causes insufficient memory errors
CHANGES FROM 1.32 TO 1.38
2. Fixed bugs
- Fixed bug that sometimes causes unexpected errors (OMP abort:)
- Fixed bug that sometimes causes exceptions when the remove button has been pressed on the Import/Export screen
CHANGES FROM 1.20 TO 1.32
1. Added Functions
- Optimised execution parameters for Edge Intensity "Auto"
- Added function that can copy original statistics data when performing Save As
- Added Compatibility Mode
CHANGES FROM 1.14 TO 1.20
1. Added Functions
- Added "Diameter Cross Measurement" to Applied Measurement
- Added Edge Intensity Graph Display function
- Added Data Backup function
- Added Statistics Data List Column Switching function