Model

SJ-H036

SJ-H060

SJ-H084

SJ-H108

SJ-H132

SJ-H156

SJ-H180

SJ-H204

SJ-H228

SJ-H252

SJ-H300

Type

H

Ion generation method

Corona discharge method

Structure

Shock-proof, resistance-coupled type

Voltage application method/applied voltage

Pulse AC method/±7,000 V

Ion balance control method

Dual I.C.C.

Ion balance

±30 V*1

Operating distance

50 to 2,000 mm

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less

Effective length

360 mm*2

600 mm*2

840 mm*2

1,080 mm*2

1,320 mm*2

1,560 mm*2

1,800 mm*2

2,040 mm*2

2,280 mm*2

2,520 mm*2

3,000 mm*2

No. of electrodes

6

12

18

24

30

36

42

48

54

60

72

Static elimination bar length

340 mm

560 mm

800 mm

1,040 mm

1,280 mm

1,520 mm

1,760 mm

2,000 mm

2,240 mm

2,480 mm

2,960 mm

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main unit

ABS resin/PC

Weight

Controller

150 g

Static elimination bar

510 g

800 g

1,000 g

1,250 g

1,450 g

1,600 g

1,850 g

2,100 g

2,400 g

2,800 g

3,250 g

*1 The value is measured under the following condition.
*2 The effective length is determined based on the static elimination range at a distance of 50 mm.

Model

SJ-H036V

SJ-H060V

SJ-H084V

SJ-H108V

SJ-H132V

SJ-H156V

SJ-H180V

SJ-H204V

SJ-H228V

SJ-H252V

SJ-H300V

Type

HV

Ion generation method

Corona discharge method

Structure

Shock-proof, resistance-coupled type

Voltage application method/applied voltage

Pulse AC method/±7,000 V

Ion balance control method

Dual I.C.C.

Ion balance

±30 V*1

Operating distance

50 to 2,000 mm

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less

Effective length

360 mm*2

600 mm*2

840 mm*2

1,080 mm*2

1,320 mm*2

1,560 mm*2

1,800 mm*2

2,040 mm*2

2,280 mm*2

2,520 mm*2

3,000 mm*2

No. of electrodes

4

8

12

16

20

24

28

32

36

40

48

Static elimination bar length

340 mm

560 mm

800 mm

1,040 mm

1,280 mm

1,520 mm

1,760 mm

2,000 mm

2,240 mm

2,480 mm

2,960 mm

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main unit

ABS resin/PC

Weight

Controller

150 g

Static elimination bar

500 g

780 g

980 g

1,200 g

1,400 g

1,550 g

1,750 g

2,000 g

2,350 g

2,700 g

3,150 g

*1 The value is measured under the following condition.
*2 The effective length is determined based on the static elimination range at a distance of 50 mm.

Model

SJ-H036C

SJ-H060C

SJ-H084C

SJ-H108C

SJ-H132C

SJ-H156C

SJ-H180C

SJ-H204C

SJ-H228C

SJ-H252C

SJ-H300C

Type

HC

Ion generation method

Corona discharge method

Structure

Shock-proof, resistance-coupled type

Voltage application method/applied voltage

Pulse AC method/±7,000 V

Ion balance control method

Dual I.C.C.

Ion balance

±30 V*1

Operating distance

50 to 2,000 mm

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less

Effective length

360 mm*2

600 mm*2

840 mm*2

1,080 mm*2

1,320 mm*2

1,560 mm*2

1,800 mm*2

2,040 mm*2

2,280 mm*2

2,520 mm*2

3,000 mm*2

No. of electrodes

4

8

12

16

20

24

28

32

36

40

48

Static elimination bar length

340 mm

560 mm

800 mm

1,040 mm

1,280 mm

1,520 mm

1,760 mm

2,000 mm

2,240 mm

2,480 mm

2,960 mm

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Controller

150 g

Static elimination bar

500 g

780 g

980 g

1,200 g

1,400 g

1,550 g

1,750 g

2,000 g

2,350 g

2,700 g

3,150 g

*1 The value is measured under the following condition.
*2 The effective length is determined based on the static elimination range at a distance of 50 mm.

For visitors who viewed this page

    Latest / Most Downloaded

      • General Catalogue Request
      • Trade Shows and Exhibitions
      • eNews Subscribe

      Static Eliminators / Ionizers