          KV Nano series

          Utilising The High Speed

          High-Speed Counter Function

          Counting by a laser sensor

          The high-speed counter setting wizard enables easy programming of initial settings, which required time and labour in the past, even without reference to manuals.

          KV-N14xx(P) KV-N24xx(P) KV-N40xx(P) KV-N60xx(P) KV-NC32T
          Number of channels 2 2 3 4 3
          Input response frequency Single phase: 100 kHz Phase difference:
          50 kHz
          Single phase: 100 kHz Phase difference:
          50 kHz
          Single phase: 100 kHz Phase difference:
          50 kHz
          Single phase: 100 kHz Phase difference:
          50 kHz
          Single phase: 100 kHz Phase difference:
          50 kHz
          Special wizard setting
          Current value refresh
          Input capture
          Comparator matching output
          Direct clock pulse output

          Revolution Counter/ Frequency Counter Function

          Measuring disk rotation

          Entered pulses are automatically converted into frequencies (Hz) or rotation speed (rpm) and stored. This built-in function will be provided in the same number as the high-speed counters, and dedicated instructions are also available.

          Cam Switch Function

          Indexing table

          Up to 32 points of output positions can be set in units of 0.1 degrees. Both absolute and incremental encoders are supported.

          Interrupt Input Function

          Labeler

          An interrupt input function offering the response time of 100 μs or less is featured as standard. Using this function together with a stop signal for positioning allows accurate motor control. It is optimum for equipment requiring high-precision stopping, such as labelers or sealers.

          KV-N14xx(P) KV-N24xx(P) KV-N40xx(P) KV-N60xx(P) KV-NC32T
          Number of points 4 4 4 4 4
          Time before
          interrupt starts
          100 μs
          * When the
          conditions are met
          100 μs
          * When the
          conditions are met
          100 μs
          * When the
          conditions are met
          100 μs
          * When the
          conditions are met
          100 μs
          * When the
          conditions are met
          Interrupt by high-speed
          counter comparator
          Interrupt by CPU positioning
          parameter comparator
          Input capture

          • PLC/HMI User Support
          • General Catalogue Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE SINGAPORE PTE LTD. 151 Lorong Chuan,#05-07, New Tech Park Lobby G, Singapore 556741
          Phone: +65-6392-1011
          E-mail: info@keyence.com.sg
          Career Opportunities: KEYENCE Career Site

          Controls