High-speed, High-precision, Wide-area Static Elimination Blower

SJ-F2000/5000 series

Catalogues View Catalogue

Blower Type Main Unit SJ-F5000

SJ-F5000 - Blower Type Main Unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • CSA

Specifications

Model

SJ-F5000

Type

600 mm type

Voltage application method

Pulse AC method

Applied voltage

±7000V

Ion balance control method

I.C.C.

Ion balance

±5 V*1

Static elimination time

Approx. 1 sec*2

Operating distance

50 mm min.

Maximum wind speed

3.5 m/s*1

Maximum air volume

6.2 m3/min

Ozone density

0.005 ppm max.

Power source input type

AC cord input

Control input

Static elimination stop input

Control output

Alarm/ Ion level alert/ Condition alert

NPN open-collector

PNP open-collector

Rating

Power voltage

100 to 240 VAC, 50/60 Hz

Power consumption

65 VA

Environmental resistance

Pollution degree

2

Overvoltage category

II

Ambient temperature

0 to +50 °C

Relative humidity

35 to 65 % RH

Weight

Approx. 5 kg

*1 Measured at a distance of 300 mm from the front of the fan
*2 Measured at a distance of 300 mm from the front of the fan and at maximum air volume

Data Sheet (PDF) Other Models