Ultra High Speed Sensing Ioniser Hybrid Type

SJ-E series

Select Language

Model

SJ-E036L

Ion generation method

Corona discharge method

Structure

Shockless resistor connection type

Voltage application method/
applied voltage

Pulse AC method/±8,000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V

Operating distance

50 to 2,000 mm

Control input

Static elimination stop input

NPN open-collector or no-voltage contact signal

Control output

Ion level alarm

NPN open-collector, 1 00 mA max. (40 VDC or less)

Condition alarm

Alarm output

Communication feature

Remote control communication

Major features

Condition alarm, ion level alarm, and alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1

Effective length

440 mm*2

Total length

350 mm

No. of electrodes

5

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

700 mA (at 24 V) or 500 mA (at 36 V)

Environmental resistance

Pollution degree

2

Overvoltage category

I

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Body

ABS / PBT / PP / LCP / PPS / SPS / SUS

Weight

670 g

*1 Contact us for details on this value when the air supply is opened and closed.
*2 Elective length indicates the static elimination rangeat 50 mm operating distance.

Model

SJ-E036H

Ion generation method

Corona discharge method

Structure

Shockless resistor connection type

Voltage application method/
applied voltage

Pulse AC method/±8,000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V

Operating distance

50 to 2,000 mm

Control input

Static elimination stop input

NPN open-collector or no-voltage contact signal

Control output

Ion level alarm

NPN open-collector, 1 00 mA max. (40 VDC or less)

Condition alarm

Alarm output

Communication feature

Remote control communication

Major features

Condition alarm, ion level alarm, and alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1

Effective length

420 mm*2

Total length

350 mm

No. of electrodes

9

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

700 mA (at 24 V) or 500 mA (at 36 V)

Environmental resistance

Pollution degree

2

Overvoltage category

I

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Body

ABS / PBT / PP / LCP / PPS / SPS / SUS

Weight

680 g

*1 Contact us for details on this value when the air supply is opened and closed.
*2 Elective length indicates the static elimination rangeat 50 mm operating distance.

Model

SJ-E036A

SJ-E060A

SJ-E084A

SJ-E108A

SJ-E132A

SJ-E156A

SJ-E180A

SJ-E204A

SJ-E228A

SJ-E252A

SJ-E300A

Ion generation method

Corona discharge method

Structure

Shockless resistor connection type

Voltage application method/
applied voltage

Pulse AC method/±8,000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V

Operating distance

50 to 2,000 mm

Control input

Static elimination stop input

NPN open-collector or no-voltage contact signal

Control output

Ion level alarm

NPN open-collector, 1 00 mA max. (40 VDC or less)

Condition alarm

Alarm output

Communication feature

Major features

Condition alarm, ion level alarm, and alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1

Effective length

420 mm*2

660 mm*2

900 mm*2

1140 mm*2

1380 mm*2

1620 mm*2

1860 mm*2

2100 mm*2

2340 mm*2

2580 mm*2

3060 mm*2

Total length

350 mm

560 mm

800 mm

1040 mm

1280 mm

1520 mm

1760 mm

2000 mm

2240 mm

2480 mm

2960 mm

No. of electrodes

5

9

13

17

21

25

29

33

37

41

49

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

700 mA (at 24 V) or 500 mA (at 36 V)

Environmental resistance

Pollution degree

2

Overvoltage category

I

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Body

ABS / PBT / PP / LCP / PPS / SPS / SUS

Weight

670 g

850 g

1,070 g

1270 g

1,500 g

1700 g

1,900 g

2,100 g

2,300 g

2,500 g

2,900 g

*1 Contact us for details on this value when the air supply is opened and closed.
*2 Elective length indicates the static elimination rangeat 50 mm operating distance.

Model

SJ-E036N

Ion generation method

Corona discharge method

Structure

Shockless resistor connection type

Voltage application method/
applied voltage

Pulse AC method/±8,000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V

Operating distance

50 to 2,000 mm

Control input

Static elimination stop input

Control output

Ion level alarm

Condition alarm

Alarm output

Communication feature

RS-485
communication /
remote control
communication

Major features

Condition alarm, ion level alarm, and alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1

Effective length

440 mm*2

Total length

350 mm

No. of electrodes

5

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

700 mA (at 24 V) or 500 mA (at 36 V)

Environmental resistance

Pollution degree

2

Overvoltage category

I

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Body

ABS / PBT / PP / LCP / PPS / SPS / SUS

Weight

670 g

*1 Contact us for details on this value when the air supply is opened and closed.
*2 Elective length indicates the static elimination rangeat 50 mm operating distance.