Metal Passage Confirmation SensorTA series

TA-340U (TA-340)

Amplifier Unit

SPECIFICATIONS

Select Language

Model

TA-340U

Sensitivity adjustment

Sensitivity selector switch and fi ne-adjustment trimmer

Output

Control output
(One shot)

Solid-state
(NPN)

100 mA (40 V max.)*1

Relay contact

SPDT 250 VAC 2 A*2

Control output

1 ms

10 ms

OFF-delay time

65 ms (contact output only)

Rating

Power voltage

110/120/220/240 VAC ±10%, 50/60 Hz

Power consumption

5 VA max.

Environmental resistance

Operating ambient temperature

0 to 50°C , No condensation

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, double amplitude: 1.5 mm, 2 hours each in the X, Y and Z axis

Accessories

Plastic screwdriver

Weight

Approx 330 g

*1 Both the solid-state and contact outputs of the amplifi er are one-shot signals; the signals turn on as the object enters the sensor head. NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter.
*2 Both the solid-state and contact outputs of the amplifi er are one-shot signals; the signals turn on as the object enters the sensor head.