SPECIFICATIONS

Select Language

Model

VG-300

Linearity

±0.1% of F.S. (F.S. = 30 mm ) *1*2

Minimumdisplayable unit

5 µm

Repeatability

5 µm*3*4

Monitor output

Output voltage

±7 V

Impedance

100 Ω

Response time

3.9 ms (number of averaging measurements : 1)

Controloutput

Control

HI, GO, LO : NPN 100 mA, 40 V max.

Controloutput

NPN open collector : 100 mA max., (40 V max.) (one-shot output time : 1.3 ms)

Controloutput

Response time

3.9 ms (number of averaging measurements : 1)

Self-timing

NPN open collector : 100 mA max., (40 V max.) (one-shot output time : 1.3 ms)

Stability output

NPN open collector : 100 mA max., (40 V max.) (N.C.)

Response time

3.9 ms (number of averaging measurements : 1)

Digital I/O

RS-232C

Key input

10 keys

Control input

- Upper/ Lower limit select input- Auto-zero input- Auto-gain input- Reset input- Laser remote input voltage contact signals- Hold input

Temperature
fluctuation

0.005% of F.S./°C (F.S. = 30 mm )

Rating

Power voltage

24 VDC ±10%, Ripple (P-P) 10% max.

Current consumption

330mA or less

Environmental resistance

Operating ambient temperature

0 to 50°C (32 to 122°F)

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm double amplitude for 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Weight

Approx 800 g

*1 F.S. (= 30 mm ) indicates the range resulting from 2.5 mm subtraction from each end of the 35 mm measuring range.
*2 Typical data obtained when the T-to-R distance was 100 mm 3.94", the receiver-to-target distance was 50 mm 1.97" and a knife edge was used tointerrupt the laser beam.
*3 When the number of averaging measurements is 16
*4 This is a typical example when the distance between the transmitter and receiver has been set to 100 mm and a knife edge has been used to block light at a position that is 50 mm from the receiver. F.S. = 30 mm displays the measurement accuracy range.