Multi-Purpose CCD Laser Micrometer

IG series

Catalogues View Catalogue

Amplifier Unit, Panel Mount Type IG-1550

IG-1550 - Amplifier Unit, Panel Mount Type

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

IG-1550

Type

Panel mount

Main unit/Expansion unit

Expansion unit

Analogue output

No

Power consumption
(including Analogue
current output)

Normal

2880 mW or less (at 30 V: 96 mA or less)*1

Power saving function (HALF)

2300 mW (at 30 V: 77 mA or less)*1

Power saving function (ALL)

2200 mW (at 30 V: 74 mA or less)*1

Digital display method

Dual 7-seg display
Upper level: Red/Green, 2 colours, 5 digits
Lower level: Green, 5 digits

Display range

-99.999 to +99.999, -99.99 to +99.99, -99.9 to +99.9, -99 to +99 (selectable)

Display resolution

1 µm, 10 µm, 100 µm, 1,000 µm (selectable)

Output

Judgment output
(selectable between NPN and PNP)

NPN (PNP) open collector x3ch, 30 VDC (Power supply voltage) or less, residual voltage 1 V (2 V) or less,
N.O./N.C. selectable Max. 50 mA/ch *2

Response time (judgment output)

1.96 to 4031.72 ms *3

Edge check output
(selectable between NPN and PNP)

NPN (PNP) open collector x1ch, 30 VDC (Power supply voltage) or less, residual voltage 1 V (2 V) or less,
N.O./N.C. selectable Max. 50 mA, *2 response time 20 ms

Analogue voltage output

None

Analogue current output

Input

Gain input

Input time: 20 ms or more, Response delay time: 120 ms or less (Nonvolatile memory (EEPROM) 1.5 s or less)

Reset input

Input time: 20 ms or more, Response delay time: 20 ms or less

Timing input

Input time: 2 ms or more, Response delay time: 2 ms or less

Zero shift input

Input time: 20 ms or more, Response delay time: 20 ms or less

Bank A input/Bank B input

Input time: 20 ms or more, Response delay time: 20 ms or less *3

Laser emission stop input

Input time: 2 ms or more, Response delay time: 2 ms or less

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %, Class 2 or LPS

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

Material

Main unit case/Front sheet: Polycarbonate, Key top: Polyacetal, Cable: PVC

Accessories

Main body × 1, Panel mounting bracket × 1, Front protection cover × 1,
Power supply and input/output cable (2 m) × 1,
Expansion cable (50 mm) × 1

Weight

Approx. 165 g (including supplied items)

*1 The power consumption with slave units installed is the total of each amplifier unit's power consumption.
*2 When expansion units are added: Max. 20 mA/ch
*3 For more details, refer to the User's Manual.

Data Sheet (PDF) Other Models