Laser Thrubeam Sensor

IB series

Select Language

Model

IB-01

IB-05

IB-10

IB-30

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10) *1

Output

170 μW

Pulse duration

30 μs

Mounting distance

0 to 2000 mm

0 to 300 mm

Measurement range

ø1 mm
(Installation distance 0 to 300 mm)
ø1 to 2.5 mm (Installation distance
300 to 2000 mm)

5 mm

10 mm

30 mm

Sampling cycle

12500 times/sec. (80 μs)

Minimum detectable object

ø8 μm
(Installation distance 0 to 300 mm)
ø8 to 50 μm
(Installation distance 300 to 2000 mm)*2

ø0.05 mm*2

ø0.1 mm*2

ø0.2 mm*2

Repeatability

5 μm
(distance 0 to 300 mm)*3

5 μm*3

10 μm*3

Temperature characteristics

±0.2% of F.S./°C*4

±0.1% of F.S./°C (±5 μm)*4

±0.1% of F.S./°C (±10 μm)*4

±0.1% of F.S./°C (±30 μm)*4

Operation indicator

Laser emission warning indicator: green LED

Environmental resistance

Ambient light

Incandescent lamp: 5,000 lux, Solar light: 10,000 lux

Incandescent lamp: 5,000 lux, Solar light: 5,000 lux

Incandescent lamp: 10,000 lux, Solar light: 10,000 lux

Ambient temperature

0 to +40 °C (No freezing)

0 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

Material

Case

PBT

Galvanised die cast

Lens cover

Glass

Cable

PVC (2 m)

Weight

Approx. 140 g

Approx. 180 g

Approx. 220 g

Approx. 510 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the centre of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm, and light is half-shielded at a position 150 mm from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average
number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm and full light is received.

Model

IB-1000

IB-1500

IB-1050

IB-1550

Type

DIN rail mount

Panel mount

DIN rail mount

Panel mount

Main unit/Expansion unit

Main unit

Expansion unit

Head compatibility

Yes

Display

Display resolution

0.01%, 0.1%, 1% (switchable)

Display range

–99.999 to 99.999, –99.99 to 99.99, –99.9 to 99.9, –99 to 99 (switchable)

Digital display method

Dual 7-segment display
Upper level:5 red digits
Lower level: 5 green digits

Dual 7-segment display
Upper level: 2-colour (green/red)
5 digits
Lower level: 5 green digits

Dual 7-segment display
Upper level: 5 red digits
Lower level: 5 green digits

Dual 7-segment display
Upper level: 2-colour (green/red)
5 digits
Lower level: 5 green digits

Operation indicator

Judgment indicator: 2-colour (green/red) LED (HI, GO, LO),
Bank indicator: Green LED x 4,
Laser emission warning indicator: Green LED,
Others: Green LED x 8, red LED x 3

Analogue output voltage

±5 V, 1 to 5 V, 0 to 5 V Output impedance 100Ω*1

No*1

Analogue current output

4 to 20 mA Maximum load resistance 350Ω*1

Control Input

Bank switch input, zero shift input

Non-voltage input*2

Control input

Zero-shift input

Laser emission stop input

Timing input

Reset input

Adjust input

Control output

Judgment output (check output)

Open collector (NPN/PNP switchable, N.O./N.C. switchable)*3

Power supply

Power consumption

1950 mW or less
(at 30 V, 65 mA max.)*4

2100 mW or less
(at 30 V, 70 mA max.)*4

1950 mW or less
(at 30 V, 65 mA max.)*4

2100 mW or less
(at 30 V, 70 mA max.)*4

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %, Class 2 or LPS

Supplied from main unit

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

Material

Case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

Weight

Approx. 150 g

Approx. 170 g

Approx. 140 g

Approx. 165 g

*1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected.
*2 The four external input wires are assigned with desired inputs.
Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
*3 Rated NPN open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 2 V or less
*4 The power consumption with slave units installed is the total of each amplifier unit's power consumption.
Example: When using one master unit (IB-1000) with two slave units (IB-1050) (1950 mW x 1) + (1950 mW x 2) = 5850 mW