Laser Thrubeam SensorIB series

IB-05

Sensor Head

SPECIFICATIONS

Select Language

Model

IB-05

Light source

Wavelength

660 nm (Visible light semiconductor laser)

Laser Class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10) *1

Output

170 μW

Pulse duration

30 μs

Mounting distance

0 to 300 mm

Measurement range

5 mm

Sampling cycle

12500 times/sec. (80 μs)

Minimum detectable object

ø0.05 mm*2

Repeatability

5 μm*3

Temperature characteristics

±0.1% of F.S./°C (±5 μm)*4

Operation indicator

Laser emission warning indicator: green LED

Environmental resistance

Operating ambientluminance

Incandescent lamp: 5000 lux
Solar light: 5000 lux

Operating ambient temperature

0 to +50°C (no freezing)

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz Double amplitude 1.5 mm XYZ each axis: 2 hours

Material

Case

Galvanised die cast

Lens cover

Glass

Cable

PVC (2 m)

Weight

Approx 180 g

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the centre of the measurement range.
*3 When distance between transmitter and receiver is set to 300 mm, and light is half-shielded at a position 150 mm from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average
number of times set to 64 times.
*4 When distance between transmitter and receiver is set to 100 mm and full light is received.