Manual-Calibration Fibreoptic SensorFS-V/T/M series (FS01)


Fibre Amplifier, Cable Type, Main Unit, NPN


Select Language



Light source

Green LED

Response time

250 μs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Orange LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

External calibration input

Non-voltage input (contact, solid state)


Control output

NPN: 100 mA (40 V) max.
Residual voltage: 1 V max.*1

Stability output

NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max.

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber


Power voltage

12 to 24 VDC ±10%, ripple (P-P): 10% or less

Current consumption

35 mA or less

Environmental resistance

Operating ambientluminance

Incandescent lamp: 10,000 lux max.,
Sunlight: 20,000 lux max.

Operating ambient temperature

-10 to +55°C (no freezing)*2

Operating ambient humidity

35 to 85% RH (No condensation)


10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours

Shock resistance

500 m/s2 in X, Y and Z directions, 3 times respectively

Case material





Approx 75 g

*1 La salida de alarma de interrupción de conexión no está disponible en ES-M2 (P).
*2 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended