Features

High-performance Micro Ionizer Head

Sensing Ionizer only 10mm in Diameter

For Full Details Download the PRODUCT CATALOG Using the SERVICE PULLDOWN Above.

Super-small Head that Can be Mounted Anywhere

Super-small Static Elimination Head
The super-small static elimination head measures only 10 mm in diameter. This direct static elimination structure featuring the ion generator in its tip ensures no attenuation in ion generation. In spite of its compact body, the head supplies a large number of ions to allow quick and accurate static elimination.
Super-small Head that Can be Mounted Anywhere
C.A.B Probe Type (SJ-M020G)
C.A.B Probe Type (SJ-M020G)
Reduces maintenance frequency (Provides a maintenance interval five times longer than convention models)
Compact & Wide (SJ-M030,SJ-M070)
Compact and Wide
 
Fastest Static Elimination in Its Class with The Pulse AC Method[Spot,Wide]
The Pulse AC Method Enables Static Elimination at Class-highest Speed.
The pulse AC method differs from conventional models in that the voltage applied to its electrode probes starts up very quickly, allowing a large ion discharge for fast and effective static elimination in a short period of time.
High-precision Ion Balance with the I.C.C. Method[Spot,Wide]
High-precision Ion Balance with The I.C.C. Method
By sensing the strength of the workpiece's electrostatic charge and providing feedback, the SJ-M automatically controls the quantity of ions generated to maintain the optimum balance.
The A.C.A.B System Keeps Static Elimination Capacity for a Long Period.
The A.C.A.B System Keeps Static Elimination Capacity for a Long Period.
The SJ-M Series uses the “Advanced Clean Air Barrier” (A.C.A.B) system that has been advanced from the conventional clear air barrier system. The A.C.A.B system provides a “laminar flow” by controlling the flow of supplied clean dry air around the electrode probe. This function remarkably reduces adhesion of foreign objects to the tip of the electrode probe, suppressing deterioration of static elimination capacity to the maximum extent.
Flat-cut Probe Reduces Dust Accumulation
Flat-cut Probe Reduces Dust Accumulation
The newly developed flat-cut probe does a remarkable job of reducing wear or dust accumulation on the tip of the electrode probe. This probe is suitable for a clean environment.
Flexible Installation of a ø10 mm Head into Existing Equipment
Flexible Installation of a ø10 mm Head into Existing Equipment
The newly developed flat-cut probe does a remarkable job of reducing wear or dust accumulation on the tip of the electrode probe. This probe is suitable for a clean environment.
The Heat-resistant Design Enlarges the Available Environmental Range.
The Heat-resistant Design Enlarges the Available Environmental Range.
The SJ-M Series provides heat resistance of up to 80°C, enabling applications even in a high-temperature environment. It is suitable for static elimination in preheating processes or in models.
Comparison of static elimination speed

Comparison of static elimination speed
Measuring conditions for comparative test conducted by KEYENCE
Charged voltage: +1 kV
Plate monitor: 150 mm x 150 mm (20 pF)
Installation distance: 50 mm
Secular change in static elimination speed (Typical)
Secular change in static elimination speed (Typical)
The above chart shows a change in the static elimination time attributable to dirt or deterioration of the electrode probe.
As the ionizer maintains a shorter static elimination time relative to the operation time, it can reduce maintenance frequency.
Tools : 0 0Save to MyFavorites0 0My Downloads0 0Email a Friend0 0Print Page0
Related Information Topics
SJ-M400 Series Product Catalog  
High-Pressure Blow Spot Type Static Eliminator
Ultra-High Speed, Sheath-Sensing Ioniser SJ-H Series  
Getting the best from Static Eliminators
Practical Static Electricity Q&A Book Vol.4  
Counter Measures Against Electrostatic Damage
General Catalog  
Just released Get your copy today.
 
Measures Against Production Line Problems
 
Practical Static Electricity Q&A Book Vol.2
 
Practical Static Electricity Q&A Book
 
Useful information for the best use of the ionizer!
Recommended Downloads
Related Product Downloads

Static Eliminator/Ioniser

Product Catalogs Instruction Manuals Technical Guide 2D CAD Data 3D CAD Data
Ultra-High Speed, Sheath-Sensing Ioniser SJ-H Series NEW
Ultra High-speed Clean Air Barrier Static Eliminator SJ-GL Series NEW
High-speed Clean Air Barrier Static Eliminator SJ-G Series
Sheath Clean Air Barrier Static Eliminator SJ-V Series NEW
Controller-integrated static eliminator SJ-R Series
High-Speed/Wide-Area Static Elimination Blower SJ-F Series NEW
Ultra high speed Static elimination blower SJ-F300 Series NEW
Super compact static elimination blower SJ-F010 Series
High-speed static elimination blower SJ-F020 Series
High-Pressure Blow Spot Type Static Eliminator SJ-M400 Series NEW
Spot type high-speed static eliminator SJ-SW Series
High-accuracy electrostatic sensor SK Series
High-performance Micro Ionizer SJ-M Series NEW
Product catalogs and manuals include both elimination head and controller information.
READ BEFORE BUYING!
Request SJ-M Series price information.
See how Keyence will ship your order the day it's received
Try the SJ-M Series free of charge.
Let the Keyence Experts answer your questions.
HOME PRODUCTS APPLICATIONS DOWNLOADS SUPPORT/SERVICES ENEWS/TOPICS COMPANY CONTACT
America Canada(English) Mexico Germany France Italy United Kingdom China Taiwan Malaysia Singapore Thailand Korea Japan