Ultra High-speed Clean Air Barrier Static Eliminator : SJ-GL Series
Support and Services
Features

Static Elimination

World's Fastest Bar Type Static Eliminator (2.7 Times Faster than Conventional Ionizers)

For Full Details Download the PRODUCT CATALOG Using the SERVICE PULLDOWN Above.

High-speed static elimination in 0.15 seconds, 2.7 times faster than before
[World's Fastest]

The SJ-GL Series uses the highly recognised pulse AC method. In the conventional method, air is pushed forward to wrap around the electrode probe.
The newly developed electrode adds pressure resistance to push the surrounding air forward without loss. With this method, the air flow transporting ions is pushed forward twice as fast* as conventional methods to achieve the world's fastest static elimination speed.
* As of December 2006 for corona discharge static elimination bars, according to KEYENCE study.
Static Elimination Capacity
 
Surrounding air flows in through the slit
Surrounding air is guided without loss to increase the air flow transporting ions and improve the static elimination effectiveness.
 
Enlarged view
Surrounding air flows forward without loss along the expelled air flow.

Open setting for static elimination sensing

With the KEYENCE original I.C.C. method, the SJ-GL automatically controls the ion generation to reach the optimal state. There is no need to make complicated initial settings after installation or maintenance.
 
The ioniser senses charged objects.
The ioniser senses charged objects.
 
SJ-GL controls static elimination based on the sensing.
SJ-GL controls static elimination based on the sensing.

Outstanding uniformity of space and high ion balance

With the pulse AC method, the SJ-GL performs static elimination while maintaining uniformity of space. The I.C.C method provides further support to sustain high-precision ion balance.
KEYENCE SJ-GL
KEYENCE SJ-GL
With the pulse AC method, each electrode alternates between generating positive (+) and negative (-) ions.
This method helps to prevent a bias from forming in the local ion balance and preserves uniformity.
Conventional product
Conventional product
With a normal DC method, each electrode generates only positive or only negative ions, which creates a bias in the ion balance along the bar length.
Comparison of static elimination speeds
Comparison of static elimination speeds
 
 
 

Electrostatic charge monitor and built-in output function

The LED bar and external output are included as standard to display the amount of charge for positive (+) or negative (-) polarity that is sensed on the target. By sending a signal to a solenoid valve, the amount of consumed air can be reduced drastically.

Notice for optimal maintenance period

The built-in automatic diagnosis function constantly monitors the ion generation level. The bar LED display and alarm output provide warnings when maintenance is required.

Pulse AC method [ Pulse AC ]

Each electrode probe alternately applies high positive and negative voltage to generate ions for both polarities.
Compared to the conventional AC method, the amount of ions generated is higher and the oscillating frequency can be changed.
AC method

Therefore, the pulse AC method can be used in any circumstance from high-speed moving workpieces to static elimination of space.
Pulse AC method

I.C.C. method [ Ion Current Control ]

By sensing the ion current generated by the potential difference between the electrode probe and the amount of charge for a workpiece, this method performs calculations and controls the supplied ions based on the amount of charge to achieve rapid static elimination.
The I.C.C. method provides high-precision ion balance control for rapid and effective static elimination.
I.C.C. method
Tools : 0 0Save to MyFavorites0 0My Downloads0 0Email a Friend0 0Print Page0
Related Information Topics
SJ-M400 Series Product Catalog  
High-Pressure Blow Spot Type Static Eliminator
Ultra-High Speed, Sheath-Sensing Ioniser SJ-H Series  
Getting the best from Static Eliminators
Practical Static Electricity Q&A Book Vol.4  
Counter Measures Against Electrostatic Damage
General Catalog  
Just released Get your copy today.
 
Measures Against Production Line Problems
 
Practical Static Electricity Q&A Book Vol.2
 
Practical Static Electricity Q&A Book
 
Useful information for the best use of the ionizer!
Recommended Downloads
Related Product Downloads

Static Eliminator/Ioniser

Product Catalogs Instruction Manuals Technical Guide 2D CAD Data 3D CAD Data
Ultra-High Speed, Sheath-Sensing Ioniser SJ-H Series NEW
Ultra High-speed Clean Air Barrier Static Eliminator SJ-GL Series NEW
High-speed Clean Air Barrier Static Eliminator SJ-G Series
Sheath Clean Air Barrier Static Eliminator SJ-V Series NEW
Controller-integrated static eliminator SJ-R Series
High-Speed/Wide-Area Static Elimination Blower SJ-F Series NEW
Ultra high speed Static elimination blower SJ-F300 Series NEW
Super compact static elimination blower SJ-F010 Series
High-speed static elimination blower SJ-F020 Series
High-Pressure Blow Spot Type Static Eliminator SJ-M400 Series NEW
Spot type high-speed static eliminator SJ-SW Series
High-accuracy electrostatic sensor SK Series
High-performance Micro Ionizer SJ-M Series NEW
Product catalogs and manuals include both elimination head and controller information.
READ BEFORE BUYING!
Request SJ-GL Series price information.
See how Keyence will ship your order the day it's received
Try the SJ-GL Series free of charge.
Let the Keyence Experts answer your questions.
HOME PRODUCTS APPLICATIONS DOWNLOADS SUPPORT/SERVICES ENEWS/TOPICS COMPANY CONTACT
America Canada(English) Mexico Germany France Italy United Kingdom China Taiwan Malaysia