Safety Light CurtainSL-C series

SL-C08L

Main Unit, General-purpose Type, 8 Optical Axes

SPECIFICATIONS

Select Language

Model

SL-C08L

Effective aperture angle

Max. ±2.5° (when operating distance is at least 3 m )

Response time

15 ms *1

Light source

Infrared LED (850 nm)

Operation mode

Turned on when light is being applied to all optical axes (excluding when the blanking function is used)

No. of beam axes

8

Detection capability

ø45 mm*2

Beam axis interval

40 mm

Lens diameter

ø5mm

Detection zone

280 mm

Protection area

365 mm

Detectingdistance

0.3 to 9 m

OSSD output

Output type

2 outputs each for PNP and NPN, Can be switched using the connection connector cable

Max. load current

300 mA *3

OFF-state voltage

2.5 V (with a cable length of 7 m )

Leakage current

100 µA maximum*4

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring resistance

2.5 Ω maximum*5

Approved standards

EMC

EMS

UL61496-1

EMI

FCC Part15 Class A

Safety

UL61496-1 (type 4 ESPE), UL61496-2 (type 4 AOPD),UL508

Current consumption

Transmitter

55 mA

Receiver

67 mA

Rating

Power voltage

24 VDC ±10% ripple (P-P) ±10% max.

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient temperature

-10 to +55°C, No condensation

Ambient temperature for storage

-10 to +60°C, No condensation

Relative humidity

35 to 85%RH (no condensation)

Storage relative humidity

35 to 95%RH (no condensation)

Operating ambientluminance

Incandescent lamp: 5,000 lux or less, sunlight: 20,000 lux or less

Vibration

10 to 55 Hz, 0.7 mm, double amplitude, 20 sweeps each in X, Y, and Z directions

Shock resistance

100 m/s2 (Approx 10G) 16 ms pulse, in X, Y, Z directions 1000 times each axis

Weight

Transmitter

Approx 255 g

Receiver

Approx 280 g

*1 OFF→ON return time is 125 ms.
*2 If the SL-CL Series, which has a minimal detection object diameter of 45 mm, is used in conjunction with the SL-R12EX, the blanking function and muting function cannot be used.
*3 Note the derating illustrated in the graph to the right when using PNP output.
*4 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected.
*5 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 Ω or less to ensure that the SL-C Series operate correctly. If using the NPN output

For visitors who viewed this page

    Latest / Most Downloaded

      • General Catalogue Request
      • Trade Shows and Exhibitions
      • eNews Subscribe

      Safety