Safety Light CurtainGL-S series

SL-U2

Power Supply Unit

SPECIFICATIONS

Select Language

Model

SL-U2

System

Switching type

Input power supply voltage

100 to 240 VAC ±10% (50/60 Hz)

Ripple/noise

240 mV p-p or less

Output capacity

1.8A

Supply voltage interruption

10 ms max.

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN61000-6-2, IEN55011 Class A, FCC Part15 Class A

Safety

EN60950-1, EN50178, UL60950-1, UL508

Rating

Power voltage

24 VDC ±10 %, Class 2

Power consumption

135 VA

Environmental resistance

Pollution degree

2

Overvoltage category

II

Insulation resistance

At least 50 MΩ
(500 VDC mega, between all external terminals and case)

Ambient temperature

-10 to +55 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Withstand voltage

1,500 VAC, 1 min. (between all external terminals and case)

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Weight

Approx. 240 g