Wire-saving AI Digital Pressure SensorAP-V40 series

AP-V42

Amplifier Unit, Expansion Unit, NPN

[Discontinued model]

This model has been discontinued.

Recommended Replaceable Products
To contact us:

SPECIFICATIONS

Select Language

Model

AP-V42

Output

NPN output

Display power

4 1/2-digit, 2-colour, 7-segment LED (Character height: 4.5 mm ) AI indicator (green) Display cycle: 10 times/s

Set and display range

-15% to +110% of F.S.

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Resolution

Standard mode

AP-41M

0.1 kPa (0.001 bar)

AP-41

AP-43

0.001 MPa (0.01 bar)

AP-44

0.1 kPa (0.001 bar)

AP-47

0.01kPa

AP-48

0.1 kPa (0.001 bar)

Focus mode

AP-41M

0.01kPa

AP-41

AP-43

0.1 kPa (0.001 bar)

AP-44

0.02kPa

AP-47

0.001kPa

AP-48

0.02kPa

Repeatability

±0.2% of F.S. or less

Linearity

±0.5% of F.S. or less

Hysteresis

Variable (0.5% of F.S. in standard mode)

Response time
(chattering prevention function)

1/2.5/5/100/500 ms (selectable)*1

I/O

Control output

Maximum NPN open-collector output: 100 mA (40 V or less),*2 residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)

Temperature characteristics

±1% of F.S. or less

I/O

Analogue output (selectable)

1 to 5 V, output impedance: 1 kΩ or less (only available on the V41; switchable with zero shift input)

Zero-shift input (selectable)

No-voltage input (with contacts, without contacts), input time: 2 ms or more (switchable with analog output on the V41)

Rating

Power voltage

12 to 24 VDC ±10% with ripple (p-p) of 10% max.

Power consumption

At 12 V

Normal

660mW (55mA)

Eco mode

480mW (40mA)

At 24 V

Normal

900mW (37mA)

Eco mode

720mW (30mA)

Environmental resistance

Ambient temperature

0 to +50°C (no freezing)

Relative humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively

Housing material

Polycarbonate

Accessories

End Unit,Head Connector, and Expansion Seal

Weight

Approx. 80 g (with 2 m cable)

*1 100 ms and 500 ms are selectable when using the AP-47.
*2 20 mA or less when extended

For visitors who viewed this page

    Latest / Most Downloaded

      • General Catalogue Request
      • Trade Shows and Exhibitions
      • eNews Subscribe