High-speed, High-accuracy CCD Laser Displacement Sensor

LK-G3000 series

Catalogues View Catalogue

Sensor Head: Multi-Purpose, Wide beam LK-G87

LK-G87 - Sensor Head: Multi-Purpose, Wide beam

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking

Specifications

Model

LK-G87

Reference distance

Diffused reflection: 80 mm, Specular reflection: 75.2 mm

Measuring range

Diffused reflection: ±15 mm, Specular reflection: ±14 mm*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR Part 1040.10), Class 2 (IEC60825-1)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. 70 x 1,100 µm

Linearity

±0.05 % of F.S. (F.S.= ±15 mm)*3

Repeatability

0.2 µm*4*5

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1000 µs (Selectable from 6 levels)

LED display

Near the centre of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±15 mm)

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Aluminium die-cast

Weight

Approx. 380 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -9 (NEAR side) to -15 mm (NEAR side) for diffuse reflection, and -8.7 (NEAR side) to -14 mm (NEAR side) for specular reflection.
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 Consult your nearest KEYENCE representative for the Class IIIa type with increased repeatability.
*5 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

Data Sheet (PDF) Other Models