Programmable ControllerKV-5000/3000 series

KV-MX1

INC Encoder, 4 Input Channels, 12 Inputs, 12 Outputs, SD Card

SPECIFICATIONS

Select Language

Model

KV-MX1

General specifications

Power voltage

Main unit : 24 VDC ±10% (supplied by the CPU unit), I/O side : 24 VDC ±10%

Operating ambient temperature

0 to +50°C (no freezing)*1*2

Operating ambient humidity

10 to 95%RH (no condensation)

Storage ambient temperature

-20 to +70°C*1

Storage ambient humidity

10 to 95%RH (no condensation)

Operating atmosphere

Minimal amount of dust and corrosive gas present

Operating altitude

2000m or less

Pollution degree

2

Noise resistance

1,500 Vp-p, pulse width : 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61000, 4-2/3/4/6)

Withstand voltage

1,500 VAC for 1 minute between the power supply terminal and the I/O terminals and between all the external terminals and the case, 500 VAC for 1 minute between the power supply terminal and the MECHATROLINK-II communication port and between the power supply terminal and FG (KV-ML16V)

Insulation resistance

50 MΩ or more (tested with a 500 VDC megger, between the PLC power supply terminal and the I/O terminals and between all the external terminals and the case)

Environmental resistance

Vibration resistance

Intermittent vibration: Frequency 5 to 9 Hz

Half amplitude : 3.5 mm*3

Intermittent vibration: Frequency 9 to 150 Hz

Acceleration : 9.8 m/s2*3

Continuous vibration: Frequency 5 to 9 Hz

Half amplitude : 1.75 mm*3

Continuous vibration: Frequency 9 to 150 Hz

Acceleration : 4.9 m/s2*3

Overvoltage category

II (when the KV-U7 is being used)

Allowable power flicker time

10 ms (conforms to the CPU unit)

Current consumption

Main unit : 30 mA or less, external I/O : 100 mA or less

Weight

Approx 160g

Performance specifications

Supported units

KV-ML16V/KV-MC40V/KV-MC20V

Input frequency

6.4 MHz maximum (2-phase 4×)

Number of counter points

INC : 4, ABS : 2 (set with KV STUDIO)

*1 This is the guaranteed range of the system.
*2 This is regulated according to the temperature below the control panel unit.
*3 Conforms to JIS B 3502, IEC61131-2
Number of sweeps : 10 times respectively in the X, Y, and Z directions (100 minutes)